We Ship World Wide - Choose an Alternate Currency
Online Catalogue | Jensen | Jensen | Steam Engine Parts | Steam Engine Parts | Parts for Jensen Model 25G
Ref: JN113
Quantity:
Generator Magnets 3 pieces with screws
Ref: JN105
Lamp Post with wire & nut
Ref: JN104
Generator Brush
Ref: JN018b
Light Bulb for 15AC Generator, 20G, 25G, 55G and 70G (and old 15bl generators)
Ref: JN009a
Jensen Drive Belts Springs 4.5 inch.
Ref: JN082
Jensen Heater Element 110 volt A/C. (With Power Cord 2.5 in Dia Boiler). Click on This Text for Assembly and Operating Instructions
Ref: JN081
Jensen Heater Element 110 volt A/C. (Without Power Cord 2.5 in Dia Boiler).Instructions for Installing a Jensen Heating ElementTake the boiler and firebox assembly off of the metal base or board. Leave the boiler & boiler straps on the firebox.Take off the insulation metal support by removing the 4 rivets. This can be accomplished in several ways:Drilling out the rivetsChiseling the rivets off from the insideUse a Dremel tool to grind the 4 rivets outInstall the heater element, start both screws in the heater element to firebox, equally tighten these screws in order to gap the terminals so they do not touch the walls of the firebox. If terminals touch the firebox walls it will cause a dead short.Next put in the 2 fire insulation sheets.Now install the fiber insulation metal support with screws & nuts provided. You may also use a pop rivet gun if you do not want to use the screws & nuts.Screw down the firebox & smoke stack support to the metal base or board.Now put on the Hayco (cord restraint) with a pair of pliers or needle nose pliers. Place the smallest part of the Hayco restraint at the bottom of the power cord and press both sides of Hayco as close to smoke stack support as you can. Now pop the attached Hayco into the hole on the smoke stack support.NOTE: ONLY FACTORY INSTALLED HEATER ELEMENTS ARE UNDER WARRANTY. Click on This Text for Assembly and Operating Instructions
Ref: JN085
Jensen Fiber Insulation for Electric Burner6 X 5 1/4 inches
Ref: JN087
Hayco Cord Restraint
Ref: JN101
Ref: JN074
Jensen Live Steam Engine Boiler with Firebox - Model # 25.(Boiler: 2 1/2 inch Diameter, Length 6 inches.)
Ref: JN063
Jensen Steam Engine Boiler - Model # 25.Boiler: 2 1/2 inch Diameter, Length 6 inches.
Ref: JN019b
Boiler Straps, set of 2 pieces for 2 1/2' boilers.(Model 75, 25, and 70 Engines).
Ref: JN102
Boiler Strap Bolts, 4 with nuts.
Ref: JN098a
Eyelet Rivets for boiler straps all engines, grounding strap electrical engines, side insulation support on firebox for electrical engines.
Ref: JN057
Jensen Steam Engine Firebox - Model # 25.
Ref: JN103
Screws for plywood bases
Ref: JN010
Jensen Smoke Stack (brick embossed for late model engines) All engines.
Ref: JN089b
Smoke Stack Support 2 1/2 in. boiler. For Electric Jensen Model 25 and 70.
Ref: JN098b
Large Rivets for fastening firebox and smoke stack support to metal base on Jensen model 70, 75.
Ref: JN045
Steam Engine Flywheel - Model # 25.3 in. diameter 1/2 in. wide
Ref: JN038
Steam Line - Model # 25.Click on picture for large view.
Ref: JN030
Cylinder Assembly, Complete-Model # 25. Same as Model 75BOTH instructions on how to take the old one off AND then, put the new one on: 1. Take the hollow steam screw out on the top front of boiler which holds the steam pipe on.2. The 2 steam chest screws that connect the steampipe to the flat part of the cylinder - take them out.3. Take the crank pin screw off (which holds the connecting rod to the crank shaft).4. Then loosen 6/32 set screw on the 2-step pulley & take it off of shaft.5. Then loosen the 6/32 set screw on flywheel and take it off of shaft.6. Loosen the 8/32 set screw on the aluminum eccentric pulley and take it off of shaft7. Put the new eccentric aluminum pulley back onto shaft, then put the flywheel onto shaft. Put the shaft back through the journal & put the 2-step pulley on.8. Put the 2 steam chest screws 6/32 x 3/4" & reversing mechanism holes lined up and tighten the 2 screws. Line up the eccentric pulley evenly to make sure it is straight and not cocked or binded.9. Tighten up the flywheel set screw & put back on the 4 1/2" spring belt on the hub of flywheel to the brass pulley on the governor.10. Now tighten the eccentric aluminum pulley onto the shaft. Then take the crank pin screw & tighten it making sure the eccentric set screw is up and the crank pin screw is down so it will be properly timed.11. Then put in the hollow steam screw into the top front of boiler.Click on picture for large view.
Ref: JN114a
Steam Cylinder attaching screws 6/32 x 3/4 set of two for models 25, 75 or 20
Ref: JN100h
Model ID Plate for Jensen 25G steam engine.
Ref: JN098c
Small Rivets for ID tags
Ref: JN099
Ladder for Model 25 or 75
Ref: JN097a
Crank Pin Screw(attaches connecting rod) Model 25,75
Ref: JN096
Reversing Lever Spring Only
Ref: JN095
Reversing Lever & Spring
Ref: JN017
Pulley, 2 step 1 3/8' diameter.
Ref: JN002
Jensen Steam Whistle, machined brass / nickel plated, (all engines)thread size 5/16 inch, 24 tap
Ref: JN003
Jensen Safety Valve, 25 psi. machined brass / nickel for all engines .Thread size 5/16 inch, 24 tap
Ref: JN004
Jensen Hollow Steam Screw, machined brass / nickel for all engines.
Ref: JN016
Pressure Gauge with Brass Adapter. Fits ALL Jensen engines.Click on picture for large view.
Ref: JN091
Round Window Ring Nut Only
Ref: JN008a
Boiler Gasket Set round style gauge.
Ref: JN005
Round Gauge Window, (Glass with Gaskets)Click on picture for large view.
Ref: JN092
Wrench only for Round Window Ring Nut
Ref: JN093
Red Handle
Ref: JN094
Pin for Red Handle
Ref: JN015
Funnel
Main Pages